top of page
BAM
BUILDING
CHIANG
RAI
Structure Type
- 5-story reinforced concrete building
Scope of Works
- Natural period monitoring of the structure by using ambient vibration method
- Structural capacity evaluation of existing structure due to seismic forces by using RSA method and determine the demand per capacity ratio of structural members
WHAT
BAM Building
WHERE
Chiang Rai
WHEN
2016



bottom of page